Hygrothermal fRsi & 2D Junction Simulator

Solid Masonry (450mm) Corner Thermal Bridge & Intermittent Heating Dynamics

Wall U-Value 0.70 W/m²K
Uninsulated: ~1.8–2.2 | Historic Target: ~0.70 | EnerPHit: ~0.15
Indoor Setpoint Temp (Ti) 20.0 °C
Outdoor Design Temp (Te) -1.0 °C
Standard Irish/UK winter design condition: -1.0 °C to 0.0 °C
Indoor Relative Humidity 55 %
Heating Regime
Thermal Physics Rules of Thumb:
  • fRsi ≥ 0.75: Compliant under Irish TGD-L / UK BR497 for dwellings (Mold threshold at 80% RH).
  • fRsi ≥ 0.70: Continental European baseline (DIN 4108-2).
  • 2D Corner Effect: Geometric thermal bridge causes the internal corner surface temperature to drop ~15–20% below the 1D field wall.
1D Wall Surface (Tsi)
--
fRsi: --
2D Corner Surface (Tsi)
--
fRsi (2D): --
Critical Mold Dew Pt (80% RH)
--
Absolute Dew Pt: --
Corner Assessment
Calculating...
--
Exterior (Te)
Thermal Gradient (°C)
Interior (Ti)